Pay attention! The new requirement KDB 484596 D01 of FCC data reference rules in the United States has been released

Author:中認聯(lián)科 time:2023-11-29 Ctr:1519

In 1023, 2023, the FCC of the United States issued a new requirement for data citation rules, KDB484596D01 Referencing Test Data V 02. 484596D01 Referencing Test Data V02 replaces 484596D01 Referencing Test Data V01, which provides guidance for the reference of test data and allows the reference of test data in the test report submitted in the related equipment authorization application. For similar equipment with multi-model application and differentiation, if EMC(RF) and RF exposure assessment data are cited to reduce the test volume, KDB inquiry consultation must be submitted to obtain FCC authorization.

The update is as follows:

Update 1: The extended terms of EMC and RF exposure data citation are introduced (the previous guidelines provided in TCBC seminars (October 2020 and April 2021) are merged), and the data of Spot check can't exceed 25% compared with the previous reference data.

更新一.png

Update 2: The query procedure based on ECR KDB provides a new guide, and the submitted ECR KDB reference data query shall meet the following standards.

When taking ECR KDB inquiry, choose "equipment conformity review (ECR)" as the first category and "data reference" as the second category. Selecting an incorrect category will require correction, thus delaying processing.

Only grantee/applicant of the same Grantee Code can submit data reference ECR. Applicants can also choose to have the testing laboratory, TCB or other authorized agents submit ECR on their behalf. Test data can only be referenced in applications under the same Grantee code. The selected products must be certified by the same assignee, or the ID change must be submitted to the same Grantee according to the provisions of Section 2.933.

After receiving the FCC's positive reply to the ECR query (that is, the FCC "accepts"), the applicant can contact TCB and provide all the information (such as test data) required for the 731 form application. This should be done for products (if not yet certified) and variant devices.

FCC's acceptance of ECR does not mean that it recognizes the validity or accuracy of the data provided. This is only a technical proof that the variant equipment meets the data reference requirements.

A copy of the ECR KDB query (indicating FCC acceptance) shall be provided to TCB and uploaded together with the attachment of Form 731 as a supporting reason for the data reference process. If necessary, ECR queries can be uploaded as long-term confidential exhibits. TCB has the right to conduct a separate KDB investigation to FCC to confirm the validity of ECR or any statement therein.

A new, separate and complete ECR is required for requests of other variants, or for changing the FCC ID for reference models certified by different transferees.

Update 3: Added examples to illustrate possible scenarios.

★ 7.1. Multi-band Cellular Handset Multi-band Mobile Phone

A cellular phone (handset) is certified as a multiband operating in a licensed commercial mobile radio service band, for example, part 22, part 24, part 25 and/or part 27 below 3GHz. Reference device has been certified for all bands, and variant device will use a reduced set of bands. Variant device has the same components as reference device, and the band reduction operation is realized by software.

In this case, the data reference process is not needed, because the test on the reference device includes all bands, thus covering all possible use cases required for compliance demonstration. All mobile phones usually have the same FCC ID, because the only difference is related to the loaded software or firmware.

If the band reduction function of a variant device is obtained by removing components from the reference device design, the data reference process can be allowed for the variant device as long as the component removal does not lead to significant changes in the transmission mode compared with the reference device. It should also be considered that for the reference RF exposure data, the most significant changes are usually those related to the near-field emission mode, and these changes may be caused by minor modifications of PCB layout or component placement.

Reference device and variant device may or may not be under the same FCC ID: this is a manufacturer's choice/application, which needs to be approved by FCC as part of the ECR KDB investigation. However, according to Article 2.907(b) of the Rules, this does not affect the authentication procedure).

★ 7.2. DFS Data Referencing DFS data reference

If client device meets the requirements of KDB 905462, DFS client device is allowed to reference DFS data.

For example, the DFS test reported by reference device includes 30 tests for each BW mode (20, 40, 80MHz) and each radar waveform. For the approved variant device (which may also have non-DFS-related changes), the DFS spot check test report may include the widest BW mode (80 MHz) and 10 tests of each radar waveform to prove the required passing percentage of each waveform.

Warm tips

ZRLK has been focusing on the testing and certification of consumer electronic and electrical products for 20 years, always paying attention to the changes of laws and regulations in various countries, and providing customers with one-stop testing and certification services to ensure that your products enter the target market quickly. If you want to know more about the requirements of FCC certification in the United States or have products that need FCC certification in the United States, please feel free to contact us, and our engineers will serve you as soon as possible!

Related Articles
  • Compliance leads to bestsellers! Key points to know for SRRC Certification of Smart refrigerators

  • CE certification for smart dishwashers: Ensuring quality and expanding the European market

  • Focus on the CCC certification of power adapters for sweeping robots, safeguarding safety and quality

  • Electric shaver battery CCC certification: A dual guarantee of safety and quality

Follow Us
亚洲国产精品无码AV| 十八禁视频网站在线观看| 色综合色国产热无码一| 97色偷偷色噜噜狠狠爱网站| 久久国产色av| 亚洲性无码av中文字幕| av人摸人人人澡人人超碰小说| 国产产无码乱码精品久久鸭| 欧美变态口味重另类在线视频| 久久精品九九亚洲精品| 欧美熟妇xxxxx欧美老妇不卡| 夜夜躁日日躁狠狠久久av| 亚洲av无码一区二区三区在线播放| 色妞ww精品视频7777| 强行糟蹋人妻hd中文| 亚洲s色大片在线观看| 性欧美丰满熟妇xxxx性| 国产69精品久久久久999小说| 免费观看羞羞视频网站| 91日韩在线| 又黄又禁久久| 无码精品国产va在线观看| 狠狠色综合网久久久久久| 醉酒后少妇被疯狂内射视频| 九色精品视频| 亚洲色无码播放亚洲成AV| 国产白浆喷水在线视频| 岛国AAAA级午夜福利片| 忘忧草在线社区www中国中文| 国产午夜福利在线观看红色一片| 日韩精品偷拍| 人妻AV无码一区二区三区| 舌头伸进去添好爽高潮| 国产成人精品免高潮在线观看| 抽搐一进一出再深一点| 久久国产精品久久久久久| 五月丁香啪啪| 久久精品国产精品亚洲艾草网| 97精品久久久久中文字幕| 亚洲国产精品第一区二区三区| 色一情一乱一伦|