Pay attention! The new requirement KDB 484596 D01 of FCC data reference rules in the United States has been released

Author:中認(rèn)聯(lián)科 time:2023-11-29 Ctr:944

In 1023, 2023, the FCC of the United States issued a new requirement for data citation rules, KDB484596D01 Referencing Test Data V 02. 484596D01 Referencing Test Data V02 replaces 484596D01 Referencing Test Data V01, which provides guidance for the reference of test data and allows the reference of test data in the test report submitted in the related equipment authorization application. For similar equipment with multi-model application and differentiation, if EMC(RF) and RF exposure assessment data are cited to reduce the test volume, KDB inquiry consultation must be submitted to obtain FCC authorization.

The update is as follows:

Update 1: The extended terms of EMC and RF exposure data citation are introduced (the previous guidelines provided in TCBC seminars (October 2020 and April 2021) are merged), and the data of Spot check can't exceed 25% compared with the previous reference data.

更新一.png

Update 2: The query procedure based on ECR KDB provides a new guide, and the submitted ECR KDB reference data query shall meet the following standards.

When taking ECR KDB inquiry, choose "equipment conformity review (ECR)" as the first category and "data reference" as the second category. Selecting an incorrect category will require correction, thus delaying processing.

Only grantee/applicant of the same Grantee Code can submit data reference ECR. Applicants can also choose to have the testing laboratory, TCB or other authorized agents submit ECR on their behalf. Test data can only be referenced in applications under the same Grantee code. The selected products must be certified by the same assignee, or the ID change must be submitted to the same Grantee according to the provisions of Section 2.933.

After receiving the FCC's positive reply to the ECR query (that is, the FCC "accepts"), the applicant can contact TCB and provide all the information (such as test data) required for the 731 form application. This should be done for products (if not yet certified) and variant devices.

FCC's acceptance of ECR does not mean that it recognizes the validity or accuracy of the data provided. This is only a technical proof that the variant equipment meets the data reference requirements.

A copy of the ECR KDB query (indicating FCC acceptance) shall be provided to TCB and uploaded together with the attachment of Form 731 as a supporting reason for the data reference process. If necessary, ECR queries can be uploaded as long-term confidential exhibits. TCB has the right to conduct a separate KDB investigation to FCC to confirm the validity of ECR or any statement therein.

A new, separate and complete ECR is required for requests of other variants, or for changing the FCC ID for reference models certified by different transferees.

Update 3: Added examples to illustrate possible scenarios.

★ 7.1. Multi-band Cellular Handset Multi-band Mobile Phone

A cellular phone (handset) is certified as a multiband operating in a licensed commercial mobile radio service band, for example, part 22, part 24, part 25 and/or part 27 below 3GHz. Reference device has been certified for all bands, and variant device will use a reduced set of bands. Variant device has the same components as reference device, and the band reduction operation is realized by software.

In this case, the data reference process is not needed, because the test on the reference device includes all bands, thus covering all possible use cases required for compliance demonstration. All mobile phones usually have the same FCC ID, because the only difference is related to the loaded software or firmware.

If the band reduction function of a variant device is obtained by removing components from the reference device design, the data reference process can be allowed for the variant device as long as the component removal does not lead to significant changes in the transmission mode compared with the reference device. It should also be considered that for the reference RF exposure data, the most significant changes are usually those related to the near-field emission mode, and these changes may be caused by minor modifications of PCB layout or component placement.

Reference device and variant device may or may not be under the same FCC ID: this is a manufacturer's choice/application, which needs to be approved by FCC as part of the ECR KDB investigation. However, according to Article 2.907(b) of the Rules, this does not affect the authentication procedure).

★ 7.2. DFS Data Referencing DFS data reference

If client device meets the requirements of KDB 905462, DFS client device is allowed to reference DFS data.

For example, the DFS test reported by reference device includes 30 tests for each BW mode (20, 40, 80MHz) and each radar waveform. For the approved variant device (which may also have non-DFS-related changes), the DFS spot check test report may include the widest BW mode (80 MHz) and 10 tests of each radar waveform to prove the required passing percentage of each waveform.

Warm tips

ZRLK has been focusing on the testing and certification of consumer electronic and electrical products for 20 years, always paying attention to the changes of laws and regulations in various countries, and providing customers with one-stop testing and certification services to ensure that your products enter the target market quickly. If you want to know more about the requirements of FCC certification in the United States or have products that need FCC certification in the United States, please feel free to contact us, and our engineers will serve you as soon as possible!

Related Articles
  • How do smart desk lamps pass CE certification? ZRLK is your escort

  • Sodium battery UN38.3 certification: a key link to ensure product safety and compliance

  • CCC certification points of large capacity charging box: battery, headphones can not be less

  • CCC certification of the earphone charging case: The rated capacity of the battery cell is less than 600mAh.

Follow Us
一本精品中文字幕在线| 精品午夜福利在线观看| 色呦呦在线观看免费视频| 午夜精品久久久久久久久第一页 | 欧美日韩一区二区三区自拍| 国产精品美女一区二区视频| 久久99精品国产99久久6尤物| 久久婷婷五月综合97色一本一本| 精品无码久久久久久久久久| chinasex喷水videos中国少妇| 久久久久亚洲av片无码v| 国产精品va在线播放我和闺蜜| 久久中文字幕人妻熟av女| 99久re热视频这里只有精品6| 久久人妻AV中文字幕| 亚洲中文一本无码AV在线无码| www婷婷av久久久影片| 国产成人av综合久久视色| 国产成人无码18禁午夜福利p| 婷婷丁香五月激情综合站| 国产偷国产偷亚洲高清日韩| 亚洲成A人片在线观看你懂的| 亚洲人成电影在线观看天堂色| 一区二区三区午夜无码视频| 日本免费精品视频| 亚洲成色WWW久久网站| 少妇人妻激情乱人伦| 国产灌醉视频一区二区| 无码一区二区三区免费| 免费精品国产自产拍在线观看图片 | 亚洲av无码一区二区乱孑伦as| 精品无人区卡卡二卡三乱码 | 播九公社成人综合网站| 啊灬啊灬啊灬快灬高潮少妇| 国产你懂的在线| 美女人妻激情乱人伦| 国产佗精品一区二区三区| 日韩少妇人妻vs中文字幕| 国产成人亚洲精品无码车a| 亚洲一区二区三区av无码| 欧美极品少妇无套实战|